The Professional Series-7 Force Gauges are among the most sophisticated force gauges available.
Like the Series 5 the Series-7 is compatible with a large range of motorized and manual test stands like the ESM-303 to 1500 series.
Combined with a wide variety of attachments this versatile gauge creates reliable test results with an accuracy of ±0,1% combined with a sampling rate of 14.000 Hz.
Available in 11 ranges from 0,5 kN (0.12 lbF) to 2,5 kN (500 lbF) the Series-7 Force Gauges cover a broad force measurement spectrum.
Equipped with the same features as the Series-5 Force Gauges the Series-7 adds, among other features, a larger memory of up to 5000 readings, a higher sampling rate and high speed continues data capture.
Other added features are user defined Unit of Measurement and a coefficient of friction (COF) unit of measurement.
The Series-7 Force Gauges can be equipped with a foot switch that can automate common force gauge and indicator functions.
Data connectivity is provided through RS-232, Mitutoyo (Digimatic), USB or analog outputs.
The Digital Mark-10 Series Force gauge range is available in a variation of 5 gauges with each gauge type available in a scale of force ranges.
Each type of gauge has its own specifications, the table below shows the main specifications of each gauge type.
All gauges types are equipped with a rechargeable battery, a back lit display and reversible aluminum housing.
The Series-# Digital Force Gauges are designed to be used for measuring tension and compression forces.
All gauges except for the Series-7 come with MESUR® Lite data acquisition software.
MESUR® Lite tabulates continuous or single point data. One-click export to Excel allows for further data manipulation.
Mark-10 Digital Force Gauges are versatile instruments, in general they are combined with additional equipment to a purposely build system to perform the required tasks.
We are happy to assist you in finding the most suitable configuration for your needs. Please contact us for more information.
Model | lbF | ozF | kgF | gF | N | kN | mN |
---|---|---|---|---|---|---|---|
M7-012 | 0,12 x 0,00002 | 2 x 0,0005 | - | 50 x 0,01 | 0.5 x 0,0001 | - | 500 x 0,1 |
M7-025 | 0,25 x 0,00005 | 4 x 0,001 | - | 100 x 0,02 | 1 x 0,0002 | - | 1000 x 0,2 |
M7-05 | 0,5 x 0,0001 | 8 x 0,002 | - | 250 x 0,05 | 2,5 x 0,0005 | - | 2500 x 0,5 |
M7-2 | 2 x 0,0005 | 32 x 0,01 | 1 x 0,0002 | 1000 x 0,2 | 10 x 0,002 | - | - |
M7-5 | 5 x 0,001 | 80 x 0,02 | 2,5 x 0,0005 | 2500 x 0,5 | 25 x 0,005 | - | - |
M7-10 | 10 x 0,002 | 160 x 0,05 | 5 x 0,001 | 5000 x 1 | 50 x 0,01 | - | - |
M7-20 | 20 x 0,005 | 320 x 0,1 | 10 x 0,002 | 10000 x 2 | 100 x 0,02 | - | - |
M7-50 | 50 x 0,01 | 800 x 0,2 | 25 x 0,005 | 25000 x 5 | 250 x 0,05 | - | - |
M7-100 | 100 x 0,02 | 1600 x 0,5 | 50 x 0,01 | 50000 x 10 | 500 x 0,1 | - | - |
M7-200 | 200 x 0,05 | 3200 x 1 | 100 x 0,02 | - | 1000 x 0,2 | 1 x 0,0002 | - |
M7-500 | 500 x 0,1 | 8000 x 2 | 250 x 0,05 | - | 2500 x 0,5 | 2.5 x 0,0005 | - |
Gauge | M7-012 – M7-100 | M7-200 - M7-500 |
---|---|---|
Load Cell Thread | #10-32 UNF | 5/16-18 UNC |
Series-7 gauges feature several functions typically found in more complex instruments, such as materials testers, data acquisition systems, and PLCs. The following unique features are highlighted:
High Speed Data Capture & Storage |
|
Footswitch Command String |
|
Automatic Data Output / Save / Zero / I/O Pin Toggle
Applicable events include:
|
|
User-defined Unit of Measurement
|
Series-7 Force Gauges are shipped as shown at left, and include the following accessories:
* The specific accessory depends on the force gauge model. See Included Accessories section for details.
Picture | Accessory | M7-012 - M7-20 | M7-50 - M7-100 | M7-200 - M7-500 |
---|---|---|---|---|
Extension Rod | G1024 | G1024 | G1031 | |
Cone | G1026 | G1026 | G1033 | |
Chisel | G1025 | G1025 | G1032 | |
V-Groove | G1027 | G1027 | G1034 | |
Flat | G1029 | G1029 | G1036 | |
Hook | G1028 | G1038 | G1035 | |
Coupling | - | G1039 | G1037 |
Series-7 Force Gauge models M7-012 tot M7-500 all have the same dimensions
All dimensions are noted in Inches with metric sizes in (mm) behind.
Accuracy | ±0,1% of full scale ±1 digit |
Sampling rate | 14.000 Hz |
Power | AC or rechargeable battery.Multi-step low battery indicator is displayed. Gauge shuts off automatically when power is too low. |
Battery life | Backlight on: up to 7 hours of continuous use Backlight off: up to 24 hours of continuous use |
Meaurement units | lbF, ozF, gF, kgF, N, kN, mN (depending on model) |
Outputs | USB/RS-232: Configurable up to 115.200 baud. Automatic output available up to 250 Hz. Including Gauge Control Language 2 for full computer control. Mitutoyo (Digimatic): Serial BCD suitable for all Mitutoyo SPC-compatible devices. Analog: ±1 VCD, ±0,25% of full scale at capacity General purpose:Three open drain outputs, one input Set points: Three open drain lines |
Configurable settings | Digital filters, outputs, automatic output (via USB/RS-232), automatic shutoff, default settings, averaging mode, external trigger, passwords, key tones, audio alarms, backlight, calibration |
Safe overload | 200% of full scale (display shows “OVER” at 110% and above) |
Weight (gauge only) | M7-012 - M7-100: 0,45 kg [1.0 lb] M7-200 - M7-500: 0,54 kg [1.2 lb] |
Shipping weight | M7-012 - M7-100: 1,4 kg [3.0 lb] M7-200 - M7-500: 1,5 kg [3.2 lb] |
Included Accessories | Carrying case with chisel, cone, V-groove, hook, flat, extension rod, universal voltage AC adapter, battery, quick-start guide, USB cable, resource CD (USB driver, MESURTM Lite software, MESURTMgauge DEMO software, and user's guide), and NIST-traceable certificate of calibration with data. |
Environmental requirements | 4 - 40°C [40 – 100°F], max. 96% humidity, non-condensing |
Warranty | 3 years |
Series-7 Professional | Series-5 Advanced | Series-4 Performance | Series-3 Basic | Series-2 Economical | |
---|---|---|---|---|---|
Accuracy | ±0,1% | ±0,1% | ±0,2% | ±0,3% | ±0,5% |
Sampling rate | 14.000 Hz | 7.000 Hz | 3.000 Hz | 2.000 Hz | 500 Hz |
Resolution | 1/5000 | 1/5000 | 1/2000 | 1/1000 | 1/1000 |
Units of measurement | lbF, ozF, gF, kgF, N, kN, mN (depending on model) | lbF, ozF, gF, kgF, N, kN, mN (depending on model) | lbF, ozF, gF, kgF, N, kN, mN (depending on model) | lbF, gF, kgF, N (depending on model) | lbF, kgF, N |
Outputs | USB, RS-232, Mitutoyo, Analog | USB, RS-232, Mitutoyo, Analog | USB, RS-232, Mitutoyo, Analog | USB | No |
- RS-232 | Configurable up to 230.400 baud | Configurable up to 115.200 baud | Configurable up to 115.200 baud | No | N/A |
- USB | Configurable up to 230.400 baud | Configurable up to 115.200 baud | Configurable up to 115.200 baud | Configurable up to 115.200 baud | N/A |
- Mitutoyo (Digimatic) | Serial BCD suitable for all Mitutoyo SPC-compatible devices | Serial BCD suitable for all Mitutoyo SPC-compatible devices | Serial BCD suitable for all Mitutoyo SPC-compatible devices | No | N/A |
- Analog | ±1 VDC, ±0,25% FS at capacity. Positive for compression, negative for tension | ±1 VDC, ±0,25% FS at capacity. Positive for compression, negative for tension | ±1 VDC, ±0,25% FS at capacity. Positive for compression, negative for tension | N/A | No |
- General purpose I/O | Three open drain outputs, one input | Three open drain outputs, one input | Three open drain outputs, one input | N/A | No |
- Set point | Three open drain lines | Three open drain lines | Three open drain lines | N/A | No |
Mesur-Lite software included | Yes | Yes | Yes | Yes | No |
Data output functionality | Automatic output or by pressing DATA button, or requesting from a PC or other device. | Automatic output or by pressing DATA button, or requesting from a PC or other device. | By pressing DATA button, or requesting from a PC or other device (currently displayed reading only). | By pressing DATA button, or requesting from a PC or other device (currently displayed reading only). | N/A |
ASCII command set for external control | Full command set | Full command set | “?” only (request current reading) | “?” only (request current reading) | N/A |
Interface w/MESUR® gauge and MESUR® Lite | Full communication | Full communication | Single point or continuous data output only | Single point or continuous data output only | N/A |
Interface with ESM303 / 750 / 1500 test stands | Full communication, including PC control | Full communication, including PC control | Limited to force data, overload protection, and force set points | N/A | No |
Data memory | 5.000 readings, with output | 1.000 readings, with output | 50 readings, with output | No | No |
Data memory deletion | Any individual data point, or clear all | Any individual data point, or clear all | Any individual data point, or clear all | N/A | N/A |
Statistic calculations and output to PC | Max, min, mean, std. dev., number of readings, with output | Max, min, mean, std. dev., number of readings, with output | Max, min, mean, std. dev., number of readings, with output | N/A | N/A |
Break detection | Yes | No | No | No | No |
1st / 2nd peak detection | Yes | No | No | No | No |
Programmable footswitch command string | Yes | No | No | No | No |
Averaging mode | Yes | Yes | No | No | N/A |
External trigger mode | Yes | Yes | No | No | No |
Analog load bar graph shown on display | Yes | Yes | Yes | Yes | No |
Set points (for pass / fail indication) | Yes with high / low indicators, markers on analog bar graph, and outputs | Yes with high / low indicators, markers on analog bar graph, and outputs | Yes with high / low indicators, markers on analog bar graph, and outputs | Yes with high / low indicators, markers on analog bar graph, and outputs | No |
Password protection | Yes, for calibration and individual keys | Yes, for calibration and individual keys | No | No | No |
Peak readings always displayed | Yes | Yes | Yes | Yes | No (Peak mode must be selected) |
Programmable audible tones | Yes | Yes | Yes | Yes | No |
Calibration procedure | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) |
Overload outputs | Dedicated pins for tension and compression | Dedicated pins for tension and compression | Dedicated pins for tension and compression | No | N/A |
Safe overloads | 150% of full scale (display shows warning at 110% and above) | 150% of full scale (display shows warning at 110% and above) | 150% of full scale (display shows warning at 110% and above) | 150% of full scale (display shows warning at 110% and above) | 150% of full scale (display shows warning at 110% and above) |