In standard version the measurement amplifier offers a voltage output. The TS 621 can be extended with one additional output. | |
Option D 2nd voltage output 0 to ±10V • selectable cut-off frequency • 0.5 - 5 - 10 - 20 Hz • setting by DIP-switches • click to view animation |
|
|
|
Option X 2nd voltage output 0 to ±10V • Additional amplification, selectable 2-, 3-, 4- or 5-times • filtered (cut-off-frequency 25Hz) • setting by DIP-switches |
|
Option A Additional current output • bipolar 0 to ±20mA • unipolar 0 to +20mA • unipolar 4 to +20mA • setting by DIP-switches |
|
Option TS621-AD Current output 0/4-20mA, filtered • bipolar 0 to ±20mA • unipolar 0 to +20mA • unipolar 4 to +20mA • cut-off frequency 0,5 / 5 / 10 / 20 Hz • setting by DIP-switches |
Sensor Types | Strain Gauge, full bridge |
Impedance Range | Minimum 150 Ohms |
Overall Accuracy | 0.1% (any portion of the range) |
Power Source Required | 19 to 36 VDC (24 VDC, typical) Optional: 9 to 18 VDC (12 VDC, typical) |
Power Supply to Sensor | 10 VDC, regulated (±5 VDC referenced to ground) |
Calibration Range | 38 to 580% |
Output from TS621 | 0-10 VDC (standard) |
Optional Outputs | Current (option A), 0-20/4-20 mA, user set Amplified voltage (option X),2X, 3X, 4X, 5X Damped voltage (option D) at 4 seconds |
Isolation between I/O | Galvanic Isolation using integrated DC-DC converter between input power & output signals |
Power Consumption | 100 mA @ 24 VDC |
Operating Temperature | 0 to 60 °C (32 to 140 °F) |
Connector Types | Screw Terminals |
Dimensions | 3.1" (H) x 1" (W) x 3.7" (D) (80 x 25 x 95 mm) |
Weight | 4 ounces (100 grams) |
Mounting Style | DIN-Rail Snap-In Installation (DIN-rail not provided) |