The Advanced Series-4 Digital Force Gauges are positioned in the middle of the Mark-10 Digital Force Gauge range. With all the features of the Series-3 Force Gauges added with features from its higher positioned siblings Series-5 and Series-7, the Series-4 can be used for many applications across all industries.
Available in ranges from 0,5 to 2500 N each Series-4 Gauge supports data transfer to a PC or other data collector via USB, RS-232, Mitutoyo (Digimatic), or analog outputs.
It features a sampling rate of 3000 Hz with an accuracy of ±0,2% of full scale and can store up to 50 readings or continues data output through the included MESUR® Lite data acquisition software.
The Digital Mark-10 Series Force Gauge range is available in a variation of 5 gauges with each gauge type available in a scale of force ranges.
Each type of gauge has its own specifications, the table below shows the main specifications of each gauge type.
All gauges types are equipped with a rechargeable battery, a back lit display and reversible aluminum housing.
The Series-# Digital Force Gauges are designed to be used for measuring tension and compression forces.
All gauges except for the series-2 come with MESUR® Lite data acquisition software.
MESUR® Lite tabulates continuous or single point data. One-click export to Excel allows for further data manipulation.
Mark-10 Digital Force Gauges are versatile instruments, in general they are combined with additional equipment to a purposely build system to perform the required tasks.
We are happy to assist you in finding the most suitable configuration for your needs. Please contact us for more information.
Model | lbF | ozF | kgF | gF | N | kN | mN |
---|---|---|---|---|---|---|---|
M4-012 | 0,12 x 0,00005 | 2 x 0,001 | - | 50 x 0,02 | 0,5 x 0,0002 | - | 500 x 0,2 |
M4-025 | 0,25 x 0,0001 | 4 x 0,002 | - | 100 x 0,05 | 1 x 0,0005 | - | 1000 x 0,5 |
M4-05 | 0,5 x 0,0002 | 8 x 0,005 | - | 250 x 0,1 | 2,5 x 0,001 | - | 2500 x 1 |
M4-2 | 2 x 0,001 | 32 x 0,02 | 1 x 0,0005 | 1000 x 0,5 | 10 x 0,005 | - | - |
M4-5 | 5 x 0,002 | 80 x 0,05 | 2.5 x 0,001 | 2500 x 1 | 25 x 0,01 | - | - |
M4-10 | 10 x 0,005 | 160 x 0,1 | 5 x 0,002 | 5000 x 2 | 50 x 0,02 | - | - |
M4-20 | 20 x 0,01 | 320 x 0,2 | 10 x 0,005 | 10000 x 5 | 100 x 0,05 | - | - |
M4-50 | 50 x 0,02 | 800 x 0,5 | 25 x 0,01 | 25000 x 10 | 250 x 0,1 | - | - |
M4-100 | 100 x 0,05 | 1600 x 1 | 50 x 0,02 | 50000 x 20 | 500 x 0,2 | - | - |
M4-200 | 200 x 0,1 | 3200 x 2 | 100 x 0,05 | - | 1000 x 0,5 | 1 x 0,0005 | - |
M4-500 | 500 x 0,2 | 8000 x 5 | 250 x 0,1 | - | 2500 x 1 | 2.5 x 0,001 | - |
Gauge | M4-012 – M4-100 | M4-200 - M4-500 |
---|---|---|
Load Cell Thread | #10-32 UNF | 5/16-18 UNC |
The Series-4 Force Gauge is supplied as a complete kit including:
Picture | Accessory | M4-012 - M4-20 | M4-50 - M4-100 | M4-200 - M4-500 |
---|---|---|---|---|
Extension Rod | G1024 | G1024 | G1031 | |
Cone | G1026 | G1026 | G1033 | |
Chisel | G1025 | G1025 | G1032 | |
V-Groove | G1027 | G1027 | G1034 | |
Flat | G1029 | G1029 | G1036 | |
Hook | G1028 | G1038 | G1035 | |
Coupling | - | G1039 | G1037 |
Series-4 Force Gauge models M4-012 tot M4-500 all have the same dimensions
All dimensions are noted in Inches with metric sizes in (mm) behind.
Accuracy | ±0,2% of full scale ±1 digit |
Sampling Rate | 3.000 Hz |
Power | AC or rechargeable battery (NiMH). Low battery indicator appears when battery level is low, and gauge powers off automatically when power reaches critical stage. |
Battery Life | Backlight on: up to 7 hours of continuous use Backlight off: up to 24 hours of continuous use |
Measurement Units | lbF,ozF,gF,kgF,N,kN,mN (depending on model) |
Outputs | USB / RS-232: Fully configurable up to 115.200 baud. Includes Gauge Control Language 2 for full computer control. Mitutoyo (Digimatic): Serial BCD suitable for all Mitutoyo SPC-compatibile devices. Analog: ±1 VCD, ±0.25% of full scale at capactiy General Purpose: Three open drain outputs, one input Set Points: Three open drain lines |
Configurable settings | Digital filters, outputs, automatic shutoff, default settings, key tones, audio alarms, calibration |
Safe Overload | 200% of full scale (display shows "OVER" at 110% and above) |
Weight (gauge only) | M4-012 – M4-100: 0,5 kg [1 lb] M4-200 – M4-500: 0,5 kg [1.2 lb] |
Shipping weight | M4-012 - M4-100: 1,4 kg [3.0 lb] M4-200 - M4-500: 1,5 kg [3.2 lb] |
Included Accessories | Carrying case, chisel, cone, V-groove, hook, flat, extension rod, AC adapter, battery, USB cable with driver, MESURgauge DEMO software, NIST-traceable certificate of calibration with data |
Warranty | 3 years |
Series-7 Professional | Series-5 Advanced | Series-4 Performance | Series-3 Basic | Series-2 Economical | |
---|---|---|---|---|---|
Accuracy | ±0,1% | ±0,1% | ±0,2% | ±0,3% | ±0,5% |
Sampling rate | 14.000 Hz | 7.000 Hz | 3.000 Hz | 2.000 Hz | 500 Hz |
Resolution | 1/5.000 | 1/5.000 | 1/2.000 | 1/1.000 | 1/1.000 |
Units of measurement | lbF, ozF, gF, kgF, N, kN, mN (depending on model) | lbF, ozF, gF, kgF, N, kN, mN (depending on model) | lbF, ozF, gF, kgF, N, kN, mN (depending on model) | lbF, gF, kgF, N (depending on model) | lbF, kgF, N |
Outputs | USB, RS-232, Mitutoyo, Analog | USB, RS-232, Mitutoyo, Analog | USB, RS-232, Mitutoyo, Analog | USB | No |
- RS-232 | Configurable up to 230.400 baud | Configurable up to 115.200 baud | Configurable up to 115.200 baud | No | N/A |
- USB | Configurable up to 230.400 baud | Configurable up to 115.200 baud | Configurable up to 115.200 baud | Configurable up to 115.200 baud | N/A |
- Mitutoyo (Digimatic) | Serial BCD suitable for all Mitutoyo SPC-compatible devices | Serial BCD suitable for all Mitutoyo SPC-compatible devices | Serial BCD suitable for all Mitutoyo SPC-compatible devices | No | N/A |
- Analog | ±1 VDC, ±0,25% FS at capacity. Positive for compression, negative for tension | ±1 VDC, ±0,25% FS at capacity. Positive for compression, negative for tension | ±1 VDC, ±0,25% FS at capacity. Positive for compression, negative for tension | N/A | No |
- General purpose I/O | Three open drain outputs, one input | Three open drain outputs, one input | Three open drain outputs, one input | N/A | No |
- Set point | Three open drain lines | Three open drain lines | Three open drain lines | N/A | No |
Mesur-Lite software included | Yes | Yes | Yes | Yes | No |
Data output functionality | Automatic output or by pressing DATA button, or requesting from a PC or other device. | Automatic output or by pressing DATA button, or requesting from a PC or other device. | By pressing DATA button, or requesting from a PC or other device (currently displayed reading only). | By pressing DATA button, or requesting from a PC or other device (currently displayed reading only). | N/A |
ASCII command set for external control | Full command set | Full command set | “?” only (request current reading) | “?” only (request current reading) | N/A |
Interface w/MESUR® gauge and MESUR® Lite | Full communication | Full communication | Single point or continuous data output only | Single point or continuous data output only | N/A |
Interface with ESM303 / 750 / 1500 test stands | Full communication, including PC control | Full communication, including PC control | Limited to force data, overload protection, and force set points | N/A | No |
Data memory | 5.000 readings, with output | 1.000 readings, with output | 50 readings, with output | No | No |
Data memory deletion | Any individual data point, or clear all | Any individual data point, or clear all | Any individual data point, or clear all | N/A | N/A |
Statistic calculations and output to PC | Max, min, mean, std. dev., number of readings, with output | Max, min, mean, std. dev., number of readings, with output | Max, min, mean, std. dev., number of readings, with output | N/A | N/A |
Break detection | Yes | No | No | No | No |
1st / 2nd peak detection | Yes | No | No | No | No |
Programmable footswitch command string | Yes | No | No | No | No |
Averaging mode | Yes | Yes | No | No | N/A |
External trigger mode | Yes | Yes | No | No | No |
Analog load bar graph shown on display | Yes | Yes | Yes | Yes | No |
Set points (for pass / fail indication) | Yes with high / low indicators, markers on analog bar graph, and outputs | Yes with high / low indicators, markers on analog bar graph, and outputs | Yes with high / low indicators, markers on analog bar graph, and outputs | Yes with high / low indicators, markers on analog bar graph, and outputs | No |
Password protection | Yes, for calibration and individual keys | Yes, for calibration and individual keys | No | No | No |
Peak readings always displayed | Yes | Yes | Yes | Yes | No (Peak mode must be selected) |
Programmable audible tones | Yes | Yes | Yes | Yes | No |
Calibration procedure | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) | Configurable number of data points (up to 10 in each direction) |
Overload outputs | Dedicated pins for tension and compression | Dedicated pins for tension and compression | Dedicated pins for tension and compression | No | N/A |
Safe overloads | 200% of full scale (display shows warning at 110% and above) | 200% of full scale (display shows warning at 110% and above) | 200% of full scale (display shows warning at 110% and above) | 200% of full scale (display shows warning at 110% and above) | 200% of full scale (display shows warning at 110% and above) |