The MiniTemp is intended for close range targets, measuring a minimum target area of 25mm (1 inch) in diameter out to a distance of approximately 200mm (8 inches), and has a 15cm (6 inch) target measurement area at 1.5m (4 feet).
Laser Point™ Single-point laser indicates the approximate center of the target spot.
Range: | -18 to 275°C |
Accuracy (23°C ambient temperature): | -1°C to 275°C ±2% or ±2°C whichever is greater -18°C to -1°C ±3°C |
Repeatability: | ±2% of reading, or ±2°C, whichever is greater |
Response time: | 500 mSec, 95% response |
Spectral response: | 7–18 µm |
Emissivity: | pre-set 0.95 |
Ambient operating range: | 0 to 50°C |
Relative humidity: | 10–95% RH noncondensing |
Storage temperature: | -20° to 65°C without battery |
Weight / Dimensions: | 227 g ; 152 x 101 x 38 mm |
Power: | 9V Alkaline or NiCd battery (included) |
Battery life (Alkaline): | 12 hrs |
Laser Class II: | Yes |
Typical distance to target: | Up to 1.5 m |
Distance to spot (D:S): | 8:1 |
Additional options: | Nylon holster |