The TI-25DL-MMX precisely measures wall thickness using ultrasonics. Materials that can be measured are all metals, ceramics, glass, and most rigid plastics. Measurements can be made from a single side!
The TI-25DL-MMX has 2 measuring modes: Single Thickness Reading mode which measures the thickness on one point and the Scan mode which measures over a larger measuring area by “dragging” the probe: the minimum thickness encountered during the scan will be displayed then.
The gauge has a built-in memory for 1000 data points that can be separated into 10 separate "batches". You can download the stored data to a serial printer or PC and with no additional costs a Windows compatible data transfer program is supplied.
The probe of the TI-25DL-MMX wall thickness gauge is waterproof and can also be submerged in water. It is ideal to use in tough field conditions because the gauge is impact-resistant and environmentally sealed.
Pulse-Echo Mode(Pit & Flaw Detection) measures from 0.63 to 500 millimeters (0.025 to 19.999 inches).
Echo-Echo Mode(Through Paint & Coatings) measures from 2.54 to 25.4 millimeters (0.1 to 1 inch).
all in a foam-fitted carrying case.
Selection Guide - Pit & Flaw Detection (Pulse-Echo) Mode | |||
---|---|---|---|
Model Number | Maximum Coating | Minimum Wall | Maximum Wall |
All Models | 0.50mm (0.020") | 1,01mm (0.100") | 152.4mm (6.000") |
Selection Guide - Thru-Paint (Echo-Echo) Model | |||
---|---|---|---|
Model Number | Maximum Coating | Minimum Wall | Maximum Wall |
TI-25M-MMX | 1.00mm (0.040") | 2.54mm (0.100") | 25.4mm (1.000") |
TI-25M-MMX-EXT | 2.00mm (0.080") | 5.08mm (0.200") | 127.0mm (5.000") |
Minimum Radius for Convex Surfaces | 8,89 mm | |
Minimum Radius for Concave Surfaces | 76,2 mm | |
Minimum Headroom | 25,4 mm | |
Minimum Sample Diameter | 3,8 mm | |
Minimum Substrate Thickness - F | NA | |
Minimum Substrate Thickness - NFe | NA |
Range | Pulse-Echo Mode (Pit & Flaw Detection) measures from 0.025 to 6.000 (up to 19.999 inches if uncoated using T-102-2000 probe)0.63 to 150 millimeters (up to 500 mm if uncoated using T-102-2000 probe). Echo-Echo Mode (Through Paint & Coatings) measures from 2.54 to 25.4 millimeters (0.1 to 1 inch) |
Resolution | 0.01 mm (.001") |
Display | 4½ - Digit, 0.5" Backlit LCD |
Velocity Range | 0.0492 to .3937 in./µs. (1250 to 10.000 meters/second) |
Probe | 5 MHz, 6.35 mm Diameter (0.25") |
Probe Wearface | PEEK (Polyethlethylketone) |
Cable | 1.2 m (4 ft.) waterproof cable with non-polarized, quick-disconnect connectors. Optional lengths up to 15 m (50 ft.). |
Temp. Limits | Ambient: -30 to 50° C (-20 to 120° F) Material: -20 to 100° C (0 to 200° F) Special high temperature probes are optionally available |
Serial Output | RS-232C (8, N, 1, user-set baud rate) |
Battery Type | Two AA batteries |
Battery Life | 200 hours |
Weight | 196 g (7 ounces) |
Size | 64 x 114 x 32 mm (2.5 x 4.5 x 1.25") |
Warranty | Gauge: 5 Years Probes: 90 Days |
Accessories Included | Probe/cable assembly. 4 oz. bottle of coupling fluid, NIST Calibration Certificate, 2 AA batteries, operating instructions, hard-plastic carrying case. |